Serostim Cool.Click 2

What is the Cool.Click 2?

The Cool.Click 2 is an HGH Injection Device designed to deliver Serostim Brand Human Growth Hormone. Both Serostim and the Cool.Click 2 are pharmaceutical products produced by EMD Serono.

What Makes the Cool.Click 2 Unique?

The Cool.Click 2 is one of the few Human Growth Hormone Injection Devices that do not use needles, making it an ideal choice for pediatric and adult patients who wish to experience the benefits of HGH Hormone Replacement Therapy without having to stick themselves with a needle every single day.

How Does the Serostim Cool.Click 2 Work?

The Cool.Click 2 can deliver Serostim HGH without a needle because it can fire Liquid Serostim directly into the skin using a pressure system. This Serostim Device launches a stream of Bio-Identical Human Growth Hormone powerful enough to pierce directly through the upper layers of the skin into the subcutaneous layer where all HGH Medications are delivered.

The Cool.Click 2 can achieve this mechanically through a high-powered spring that controls a piston which forces the Serostim Growth Hormone to move at high velocity. To prep for your daily HGH Dose, simply wind a trigger on the device to coil up the spring, and press the trigger on the side of the device as the tip is pressed against the skin to launch the Serostim into your system!

What are the Advantages of the Cool.Click 2

As we mentioned previously, the Cool.Click 2 is highly desirable because it does not use needles to deliver the injections. The product is also great because you can quickly and easily go about your daily HGH Injections once you learn how to use it.

What are the Disadvantages of the Cool.Click 2?

Because of the Cool.Click 2 is a complex mechanical device with electronic components; it is more expensive than Pens and other HGH Products. It also does have an initial learning curve, but once patients understand the process, it is straightforward to use.

How Can I Buy the Serono Cool.Click 2 for Needle-less Human Growth Hormone Injection.

The Cool.Click 2 is one of many Human Growth Hormone Devices and Products the Conscious Evolution Institute offers. Suppose you are interested in this HGH Injection Device. In that case, we can have it shipped to your home and the necessary HGH Cartridges or HGH Vials as soon as we diagnose your need for Bio-Identical Human Growth Hormone Therapy.

We also offer a highly competitive pricing structure to get your HGH Device for the most efficient price. We also offer a wide array of payment plans to make it easy to get the treatment you need to restore your natural Hormone Balance.

Serostim Cool.Click 2 Device Instructions

How to Set Your Dosage with the Cool.Click 2

  • With one hand, hold the base of the device. With the other hand, grip the front of the device and its cap. Turn the base of the Cool.Click 2 until the two ends meet.
  • Take off the cap and turn on the device by pressing the On/Off button.
  • A key comes with the device, designed to help you set the dose. Push the key into the corresponding keyhole on the front casing of the device until the two prongs on the key activate the Dose Settings. Remove the key and set it aside.
  • Check the display. It should be flashing.
  • Briefly press the On/Off button. You can press the button as needed to change the dosage settings to those recommended for your HGH Replacement needs.
  • After choosing the setting, you desire, use the key again. Upon activation, it will lock in your chosen settings and remember them no matter what until you go through the same process again.

How to Attach the Piston and Nozzle to the Cool.Click 2

  • Open the package, which seals the assembly for both the piston and the nozzle
  • Take the Cool.Click 2 HGH Device and hold the front and back portions of the device. Rotate the back end of the device so that the front and back lock into place.
  • Take off the cap and draw back the locks designed to hold the nozzle in place.
  • Push the piston and nozzle so the piston will rest against the spring.
  • Press down on the Cool.Click Nozzle until the piston locks into place.
  • Release the locks to return to in place, holding the nozzle and piston in place. Make sure you hear a click.
  • Make sure you built the device correctly. Tug gently on the nozzle and ensure it is one with the rest of the device. Don't take off the nozzle until you are ready to replace it.

 

Information regarding the preparation of Serono HGH Cartridges and Vials

The Cool.Click 2 is designed to work with most Serono Recombinant HGH Products, including Serostim Vials and Cartridges. All forms of HGH Injection Therapy come with specific instructions about reconstitution of the lyophilized HGH solution.

The way that Serono HGH Products are connected to the Cool.Click 2 is via connectors.

There are two forms of the connector, one of which is designed to fit vials, the other of which is designed to fit cartridges. When you receive the connector, it will be enclosed in a sealed or sterilized package. Do not use the product if the package appears tampered with or is torn.

Before attaching the connector, make sure that the product is not expired. After you make sure, your product is in date, follow the specific instructions outlined for the individual HGH Product.

How to Attach the Human Growth Hormone Vial or Cartridge to the Cool.Click 2

  • Hold the front and back of the Cool.Click 2, with the cap attached, and twist the device so that both sides are connected.
  • Take off the cap and turn the Serostim Cool.Click 2 on.
  • Take off the protective shield from the vial or cartridge connector.
  • Link the specific connector with the nozzle on the device.
  • Handle the Cool.Click 2 facing up and down, with the vial or cartridge facing the ceiling. Make sure you are looking directly at the display. Turn the base of the HGH Device in a manner that will start to take Serostim HGH into the nozzle. The screen will show precisely how much Bio-Identical Human Growth Hormone is in the nozzle.
  • After your dose on the screen, wind the device one more complete turn and gently agitate the nozzle to free any clinging bubbles, then rewind the device to evacuate the bubbles. Repeat the wind-unwind cycle until no more bubbles are present.
  • Remove the Vial or Cartridge from the Cool.Click 2 and recap the connector.

 

How to Administer Your Serostim Dose with the Cool.Click 2

  • Screw the rear casing so that it links fully with the front casing of the device. You may or may not hear a click as it screws in place.
  • Turn on the Cool.Click 2. Make sure the display reads 0.00. If you see three eights flashing, the device is not correctly tightened. Repeat step one.
  • Attach the nozzle of the HGH Device to your vial or cartridge connector.
  • Wind the device until it draws the appropriate dose of Serostim HGH. The dose will show up on the display.
  • Wind the Cool.Click 2 one extra time. Flick or tap at the side of the device so that any trapped air bubbles float up to the device's tip.
  • Rewind one rotation to return to your ideal dose, then check the nozzle for air bubbles. If you still see bubbles, return to step five and repeat until the nozzle no longer has bubbles.
  • Pull the nozzle away from the Cool.Click 2 Vial or Cartridge Connector. Your dose is ready to be administered.
  • Clean the area where you intend to deliver the Serostim HGH Needleless Injection with an alcohol swab. Be patient for the wetness to dissipate.
  • Press the nozzle to your chosen administration site. Firmly click the trigger at the top of the device while pressing toward the skin to release the Serostim HGH into your system.
  • Keep the nozzle pressed against the skin for around three seconds before moving the Cool. Click 2 away.
  • Apply pressure to the HGH Injection Site with sterile gauze for around thirty seconds.
  • Wipe the nozzle clean with a new alcohol swab. Cap the Cool.Click 2 and Return the Serostim Cartridge or Vial to the Refrigerator. Don't refrigerate the Cool.Click 2. Keep it in a dry, safe place.

 

How to Take Care of Your Serostim Cool.Click 2

  • The Cool. Click 2 should be stored in a safe environment between 50 and 104 degrees.
  • Store the product in a relatively dry environment.
  • Always keep the Cool.Click 2 Device clean. It can be washed with mild detergent and a moist cloth.
  • Never get the internal components of the Cool.Click 2 wet. Never dip in water.
  • Don't place the HGH Delivery Device in direct exposure to the sun.
  • Do not refrigerate the Serono Cool.Click 2.
  • Keep the device in its storage container when not using it.
  • This Serono HGH Device is only designed to be used for three years. Discard after three years and arrange to have a new device shipped if necessary.

Serostim Cool Click 2 Helpful Tips

Before injecting Bio-Identical Serostim HGH, gather your tools in a dry, clean area. The following are the tools that you'll need to perform a routine injection:

  • Alcohol Swabs
  • Sterile Cotton or Gauze
  • Serostim Reconstitution Kit or HGH Cartridge Connector
  • Piston and Nozzle
  • The Cool.Click 2
  • Never activate the Cool.Click 2 while the nozzle still contains air.
  • Never activate the Cool.Click 2 without first connecting the nozzle.
  • Before every injection, check the dose in the nozzle to ensure no air is caught between the nozzle and the piston.
  • If you accidentally put too much Serostim HGH in the nozzle, just push the HGH back into the vial or cartridge and restart the process.
  • Always leave the Cool.Click 2 capped when you aren't using it
  • Always follow your physician's advice regarding HGH Replacement Therapy
  • Always read all documentation with your medical treatment

 


Please Contact Us Below For Further Interest

Your Name (required)

Your Email (required)

Your Phone (required)

Select Your Program:

Select Your State:

Select Your Age (30+ only):

Confirm over 30 years old:  Yes

Confirm United States Resident?  Yes



Related Posts

How useful was this post?

Click on a star to rate it!

Average rating 5 / 5. Vote count: 1

No votes so far! Be the first to rate this post.

Word Count: 1673